Aditi Chopra
Anju Cecil
ID
 Email src
Rajalaksmanan Eshwaramoorthy
Rubin S. John
Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Tamil Nadu, India
Department of Periodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Tamil Nadu, India
Department of Biomaterials, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Tamil Nadu, India
Department of Oral and Maxillofacial Surgery, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Tamil Nadu, India
Received: 28 July 2023 / Accepted: 18 August 2023 / Published: 30 December 2023

Abstract

Introduction and aim. Inflammation, cell proliferation, matrix deposition, and tissue remodeling are all elements of the well-structured and well-coordinated process of wound repair. The aim of this study was to analyze the effect of genistein and nicotine on polyglycolic acid (PGA) and vicryl sutures.

Material and methods. Genistein and nicotine were isolated and solution was prepared and the suture material PGA and vicryl were immersed in the solution and dried. They were tested for their tensile strength and degradation values after immersion in artificial saliva (on the first day and on the 14th day). The sutures were also seen under a scanning electron microscope (SEM) for its uniform coating and the mixture formulation of genistein and nicotine were tested for their anti-inflammatory and antioxidant activity using protein denaturation assay and 2,2-diphenyl-1-picrylhydrazyl assay respectively.

Results. Nicotine has a high anti-inflammatory activity on the suture material, whereas Genistein has an insignificant anti-inflammatory effect. The mixture formulation has a relatively similar anti-inflammatory effect when compared to the control. The SEM analysis shows a uniform coating of the formulation on the PGA and vicryl sutures. In comparison, PGA has shown lesser tensile strength and hence higher degradation ability.

Conclusion. Nicotine and Genistein affect the tensile strength and degradation properties of the sutures.

 

Cite

Chopra A, Cecil A, Eshwaramoorthy R, John RS. An in vitro study for the evaluation of morphological and biochemical characteristics of absorbable sutures coated with genistein and nicotine. Eur J Clin Exp Med. 2023;21(4):742–749. doi: 10.15584/ ejcem.2023.4.13

This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited